Photonic Crystal Fiber -
Skip to content
Inovatif, Berkepribadian dan Mandiri
facebook
youtube
instagram
Program Studi Teknik Industri Terbaik di Medan Sumatera Utara yang Merupakan Jurusan dari Fakultas Favorit di Sumut Yaitu Fakultas Teknik UMA
Call Support 0812-1971-4223
Email Support [email protected]
Location Jalan Kolam No. 1 Medan Estate
Jalan PBSI No. 1 Medan Estate
  • HOME
  • PROFIL
    • AKREDITASI
    • FUNGSIONARIS
    • STRUKTURAL
    • VISI, MISI dan TUJUAN
  • AKADEMIK
    • INFORMASI AKADEMIK
      • AKADEMIK ONLINE
      • E-LEARNING
      • JURNAL TEKNIK INDUSTRI
    • JADWAL AKADEMIK
      • JADWAL KULIAH
      • JADWAL PRAKTIKUM
      • JADWAL KRS
      • JADWAL SEMESTER ANTARA
      • JADWAL UJIAN
        • UTS
        • UAS
      • JADWAL WISUDA
      • JADWAL SEMINAR/SIDANG
    • KALENDER AKADEMIK
    • KURIKULUM
  • AKTIVITAS PRODI
    • KEGIATAN PRODI
    • PRESTASI PRODI
  • MAHASISWA
    • BEASISWA
      • SYARAT DAN KETENTUAN PENERIMA KIP KULIAH
      • BEASISWA BANK INDONESIA (BI)
      • Beasiswa YPHAS Bagi Siswa/I Yang Berprestasi di Sekolah (Ranking I, II dan III)
      • Beasiswa YPHAS Bagi Mahasiswa/I Bersaudara Kandung
    • SISTEM INFORMASI
      • APIK
      • OPAC
      • WEBMAIL
      • DATA MAHASISWA
      • BLOG MAHASISWA
      • JURNAL MAHASISWA
      • AOC
      • ELEARNING
    • PRESTASI MAHASISWA
  • DOSEN
    • PENASEHAT AKADEMIK
    • BLOG DOSEN
    • AKTIVITAS DOSEN
    • PRESTASI DOSEN
    • JURNAL DOSEN
    • AOC
    • DOSEN PRODI
    • TKTD
    • ELEARNING
    • WEBMAIL
    • OPAC
  • ALUMNI
    • TRACER STUDY
    • DATA ALUMNI
    • LAYANAN ALUMNI
    • AKTIVITAS ALUMNI
    • PRESTASI ALUMNI
  • LABORATORIUM
    • INFORMASI LABORATORIUM
    • APLIKASI LABORATORIUM
  • ARSIP
    • SK Mahasiswa
    • DOKUMEN
    • PENGUMUMAN
  • HUBUNGI KAMI

Photonic Crystal Fiber

Posted on 7 January 202216 January 2023 by industri
0

Floor plasmon resonance (SPR) sensors have grown in popularity owing to their sensitivity, precision, and capacity for a ramification of packages, which includes detection, monitoring, and sensing, among others. Sensitivity and resolution are areas in which this technology has room for development. A Photonic biosensor primarily based on an uneven slotted PCF shape with extraordinarily high sensitivity has been described and theoretically investigated. This excessive performance sensor is built and absolutely characterized using finite detail technique in COMSOL Multiphysics software program environment. Sensitivity and determination are analyzed as performance parameters for the proposed sensor. Numerical simulation exhibits the maximum wavelength-sensitivity of 1100 nm/RIU with 9.09 × 10-6 RIU decision inside the extensive measurement range of refractive index from 1.30 to one.44. A polarization controller may be used to satisfactory–tune this extraordinarily touchy and huge-ranging refractive index sensor to fulfil a diffusion of practical needs. that is achieved with the attention of the version in the refractive index (RI) of the analyte channels. In comparison with in advance PCF-based sensors, the fiber design structure is simple, symmetrical, simple to supply, and value–effective. due to the asymmetric air holes and better sensitivities of the refractive index detector, it’s miles feasible to pick out biomolecules, biochemicals and different analytes.
surface plasmon resonance (SPR) sensors have received Photonic quite a few interest these days due to their wonderful sensitivity, precision, and capacity to reveal objects in actual time. Bioanalytical analyte detection, environmental monitoring, biosensing, and chemical detection have all used SPR sensors [1] [2] [3]. Otto and Kretschmann prisms are the forms of SPR sensors which are used most of the people of the time [4] [5]. a good way to create floor plasmon resonance at attenuated maximum mirrored image, prism-based SPR sensors employ an evanescent electric discipline. This permits photon power to be transferred to the floor plasmons. nonetheless, such sensors are huge and have movable mechanical elements. consequently, they’re no longer suitable for distant sensing applications. Researchers have studied each theoretical and experimental components of optical fiber-based SPR sensors [6] [7]. it’s miles viable to bypass the restrictions of prism-primarily based SPR sensing by way of the use of optical fibers within the SPR sensor era.
In comparison, fiber optic sensors are extremely flexible, lightweight, and capable of long-distance software. as a result of their small layout place and smaller recognition angle, fiber-based SPR sensors [1] have restrained use. those plasmonic PCF sensors, on the other hand, have acquired significant interest and research because of their better layout flexibility than optical fiber-primarily based SPR sensors. whilst mild travels via the section of PCF SPR sensors called the middle-cladding place, an evanescent area is produced. for you to prevent the unfastened electron at the steel-dielectric contact from transferring, the evanescent discipline creates an SPW. At resonance wavelength, the effective refractive indices of the core mode and the SPP mode are same. A widespread peak in Photonic essential mode dissipation of power can be observed as a result of the full electricity being transported from core to SPP modes all through this system. A version in the interfacial refractive index reasons adjustments in the resonant wavelength. This phenomenon explains why PCF based totally plasmonic sensors may additionally locate absolutely unknown analytes. A PCF primarily based plasmonic sensor’s performance is heavily influenced through the plasmonic metallic surface it employs. Aluminium alloys, silver, gold and copper are the maximum not unusual assets of metallic excitons [7] [8].
There are certain obstacles to the considerable usage of silver as a plasmonic material, however, due to silver’s susceptibility to oxidation in water. because of this, sensor overall performance might be sacrificed so that you can save you the oxidation issue (e.g., by using using gold on a silver layer) [9]. although aluminium has a high ionization depth, its oxidation hassle, interband transition loss and optical damping, make it ineffective for plasmonic packages [10].
Gold is chemically inert, biocompatible, and water solid. it is possible to use the plasmonic metallic coating both internal or externally to the fiber. internal deposition involves metallic coating and filling specific air holes in the PCF structure with analyte, that’s difficult in fact. In externally plasmonic metallic–lined PCF primarily based SPR sensors [3], manufacturing is easy and straightforward since the metallic is placed on top of the PCF shape. Slotted air hollow based totally PCF sensors [11] [12], D-fashioned PCF primarily based sensors [13] and upgraded outside Photonic crystal fiber sensors [14] [15] are the most notably used outdoors metallic coated PCF based totally plasmonic sensors. A side–polishing procedure is used to create the D-formed sensors. The sensor’s performance is dependent on right polishing. steel and analytic layers also are put close to to the PCF core. D-formed PCF sensors are extra sensitive than normal PCF sensors because they have got a stronger coupling among the fundamental core mode and the floor plasmon polariton mode. The sensor length is confined by way of the more confining loss in D-fashioned SPR sensors [16]. current studies has proven that a few PCF based SPR sensors with an externally carried out steel coating have a extra sensitivity [17] [18].
In reference [17], the authors endorse a consistently solid core PCF based plasmonic sensor that has a wavelength sensitivity of 4000 nm/RIU for analyte RI values ranging from 1.33 to 1.37. PCF sensors with dual cores can come across analyte RI within the range of 1.33 – 1.40 [18] with a most sensitivity of 9000 nm/RIU. in addition to the theoretical studies, a ramification of plasmonic PCF sensors were intensively investigated [16] [17] [18]. inside the reference [19], a multimode fiber-photonic crystal fiber-multimode fiber manufactured gold-coated PCF SPR sensor for characterisation of protein in biological samples is described. This sensor changed into produced the usage of 3 extraordinary styles of fiber. The capability of this sensor has been tested via considerable trying out.
An analyte or chemical may be detected with the aid of a biosensor if it carries biological components (including glucose, protein, etc.). A organic sample’s concentration can be determined with the aid of the bodily features of the pattern itself, consisting of its refractive index, viscosity, and specific gravity. The RI tiers from 1.335 to 1.345 for urine glucose concentrations from zero to ten gm/dl [20]. size of the RI allows for the detection of a huge style of organic additives [20] [21] [22] [23] [24], along with the glucose content material in urine and the protein awareness in plasma. A honest and easy plan for the construction of a gold coated, asymmetrically slotted, PCF-SPR sensor that may degree analyte RI within the range of one.30 to one.44 has been furnished on this research. Over the PCF framework, the plasmonic cloth is placed. due to the fact gold is chemically strong, it’s far selected as the energetic plasmonic material. by way of dripping or flowing the analyte over the gold, the analyte may be maintained in contact with it. The sensor’s behaviour may be evaluated via using interrogation techniques that use amplitude and wavelength. The primary intention of our research is to boom biosensor sensitivity the usage of the best and maximum sensible design feasible while decreasing production problems and fees. with the aid of replacing the symmetric air hole with an asymmetric one, we preserve performance whilst reducing the entire variety of air holes. The easy nature of the sensor’s format lends itself to smooth manufacturing utilizing the three-D printing process. on the way to get the highest possible tiers of overall performance from the sensor, many structural elements, consisting of such metallic layer thickness, pitch and air-hole diameters are subjected to optimization.

 

View this post on Instagram

 

A post shared by Teknik Industri UMA (@industri.uma)

Berita
Wisuda Periode I Tahun 2026: Rektor UMA Tekankan Lulusan Harus Mampu Hadapi Perubahan di Era Transformasi Digital
Universitas Medan Area (UMA) kembali menegaskan komitmennya dalam mencetak sumber...
Rektor Universitas Medan Area Buka PMDK Periode 1 Tahun 2026, Bekali Calon Wisudawan Hadapi Dunia Kerja Digital
Universitas Medan Area (UMA) melalui Biro Pengembangan Inovasi dan Karir...
IMTI Prodi Teknik Industri UMA Gelar Workshop Manajemen Mutu ISO 9001: Bekal Karier Profesional bagi Mahasiswa
Medan, 2026 – Dalam upaya meningkatkan kompetensi dan daya saing mahasiswa...

KAITAN UMA

LOKASI FAKULTAS TEKNIK UMA

KAMPUS I :

Jln. Kolam Nomor 1 Medan Estate
Jln. PBSI, Medan 20223
Telepon : (061) 7360168
Call Center : 0811-6013-888

KAMPUS II :

Jln. Sei Serayu No. 70 A, Medan 20122
Jln. Setia Budi No. 79 B, Medan 20122
Telepon : (061) 42402994
Call Center : 0811-6013-888

Silahkan kunjungi juga website Prodi :

  • Teknik Sipil : sipil.uma.ac.id
  • Teknik Elektro : elektro.uma.ac.id
  • Teknik Mesin : mesin.uma.ac.id
  • Arsitektur : arsitektur.uma.ac.id
  • Teknik Informatika : informatika.uma.ac.id

 

Copyright © 2016 - 2026 Prodi Teknik Industri- Universitas Medan Area