Inner Electrical Resistivity Method -
Skip to content
Inovatif, Berkepribadian dan Mandiri
facebook
youtube
instagram
Program Studi Teknik Industri Terbaik di Medan Sumatera Utara yang Merupakan Jurusan dari Fakultas Favorit di Sumut Yaitu Fakultas Teknik UMA
Call Support 0812-1971-4223
Email Support [email protected]
Location Jalan Kolam No. 1 Medan Estate
Jalan PBSI No. 1 Medan Estate
  • HOME
  • PROFIL
    • AKREDITASI
    • FUNGSIONARIS
    • STRUKTURAL
    • VISI, MISI dan TUJUAN
  • AKADEMIK
    • INFORMASI AKADEMIK
      • AKADEMIK ONLINE
      • E-LEARNING
      • JURNAL TEKNIK INDUSTRI
    • JADWAL AKADEMIK
      • JADWAL KULIAH
      • JADWAL PRAKTIKUM
      • JADWAL KRS
      • JADWAL SEMESTER ANTARA
      • JADWAL UJIAN
        • UTS
        • UAS
      • JADWAL WISUDA
      • JADWAL SEMINAR/SIDANG
    • KALENDER AKADEMIK
    • KURIKULUM
  • AKTIVITAS PRODI
    • KEGIATAN PRODI
    • PRESTASI PRODI
  • MAHASISWA
    • BEASISWA
      • SYARAT DAN KETENTUAN PENERIMA KIP KULIAH
      • BEASISWA BANK INDONESIA (BI)
      • Beasiswa YPHAS Bagi Siswa/I Yang Berprestasi di Sekolah (Ranking I, II dan III)
      • Beasiswa YPHAS Bagi Mahasiswa/I Bersaudara Kandung
    • SISTEM INFORMASI
      • APIK
      • OPAC
      • WEBMAIL
      • DATA MAHASISWA
      • BLOG MAHASISWA
      • JURNAL MAHASISWA
      • AOC
      • ELEARNING
    • PRESTASI MAHASISWA
  • DOSEN
    • PENASEHAT AKADEMIK
    • BLOG DOSEN
    • AKTIVITAS DOSEN
    • PRESTASI DOSEN
    • JURNAL DOSEN
    • AOC
    • DOSEN PRODI
    • TKTD
    • ELEARNING
    • WEBMAIL
    • OPAC
  • ALUMNI
    • TRACER STUDY
    • DATA ALUMNI
    • LAYANAN ALUMNI
    • AKTIVITAS ALUMNI
    • PRESTASI ALUMNI
  • LABORATORIUM
    • INFORMASI LABORATORIUM
    • APLIKASI LABORATORIUM
  • ARSIP
    • SK Mahasiswa
    • DOKUMEN
    • PENGUMUMAN
  • HUBUNGI KAMI

Inner Electrical Resistivity Method

Posted on 3 December 202029 December 2022 by industri
0
Nuclear power flowers (NPPs) are taken into consideration as the main supply for producing energy nowadays in some nations. The impact of effect of heavy absolutely loaded aeroplane which include (Boeing 747-200c) causes leakage of the radiation through the cracks generated on the external RC containment of NPPs, and this ends in intense damage for humans and towns. on this studies paper, external RC containment is modeled using ANSYS and hit by means of Boeing 747-200c which is the heavier aeroplane compared to other jets and reasons severe harm for external RC containment. similarly, the impact region for Boeing 747-200c is considered at 30 m vertical peak. RC containment reaction changed into studied after the effect of an aeroplane and a proposed structural health tracking technique is implemented the usage of embedded sensors so that you can hit upon and find the embedded cracks this is generated due to the effect of effect of heavy aeroplane. It changed into concluded that RC containment is unbroken besides for the impact vicinity which is broken. An experimental application was implemented on a part of the element in ANSYS that’s away from the effect location. 4 specimens had been solid the usage of heavy weight concrete in laboratory. 3 cracked specimens consist of various lengths of vertical cracks which represent specific times of effect so that it will reflect crack propagation as in ANSYS. The cracks are simulated internal laboratory specimens using failure standards. The parameters utilized in detecting the cracks for specimens are the percentage change in electrical resistivity and Decimal Logarithm Resistivity Anisotropy (DLRA) at which they deliver an excellent indication for the presence of the crack.
Structural health monitoring (SHM) is defined as monitoring the integrity of systems and detecting the harm in real-time. There are one-of-a-kind techniques which could investigate the fitness tracking of RC structures the use of unique gear consisting of dynamic response measurements, pressure variations and versions in electrical resistivity in concrete. electrical resistivity measurements degree the harm propagation in concrete and the corrosion of steel reinforcement [1]. Structural fitness tracking is non-stop real-time statistics which can be collected for studying the damage propagation in RC structures. furthermore, electric resistivity is considered as a non-unfavourable trying out technique for strengthened Concrete (RC) factors and can be utilized in detecting cracks [2] [3]. therefore, electric conductivity may be used to stumble on and monitor crack initiation and propagation in concrete [2]. The blessings of the electrical resistivity trying out technique are taken into consideration low in value, easy and efficient. In widespread, electric resistivity of concrete is related to the microstructure of the cement matrix, its pore shape and pore length distribution [4]. In concrete, the present day flows via the pore liquid in the cement paste [5]. moreover, conduction of strength through concrete may additionally take area in two approaches, electronic and electrolytic. Electrolytic conduction occurs via movement of ions in concrete within the pore answer while the electronic conduction takes place through the motion of unfastened electrons within the conductive media. thus, concrete electrical resistivity is a geometry independent material property that describes the electrical resistance, the ratio among the applied voltage and the ensuing contemporary in unit cellular geometry [6].

several strategies for measuring electric resistivity have been referred to on this literature [7]. Wenner probe method is the widely used dependable approach [7] [8] for measuring electrical resistivity. The factors that control electric resistivity capabilities in concrete are the hydration diploma of the cement paste of concrete which would result in an increase of electrical resistivity with appreciate to time. furthermore, other influential elements affecting electrical resistivity measurements encompass the relative humidity, the concrete temperature, and the ions concentration and their mobility inside the pore solution [9]. the electric resistivity of concrete can be measured using numerous methods [10]. normally, electrodes are placed on the floor and the resistance is measured as in Wenner test. The resistivity is often related to corrosion and durability overall performance of concrete [11].

 

View this post on Instagram

 

A post shared by Teknik Industri UMA (@industri.uma)

Berita
Wisuda Periode I Tahun 2026: Rektor UMA Tekankan Lulusan Harus Mampu Hadapi Perubahan di Era Transformasi Digital
Universitas Medan Area (UMA) kembali menegaskan komitmennya dalam mencetak sumber...
Rektor Universitas Medan Area Buka PMDK Periode 1 Tahun 2026, Bekali Calon Wisudawan Hadapi Dunia Kerja Digital
Universitas Medan Area (UMA) melalui Biro Pengembangan Inovasi dan Karir...
IMTI Prodi Teknik Industri UMA Gelar Workshop Manajemen Mutu ISO 9001: Bekal Karier Profesional bagi Mahasiswa
Medan, 2026 – Dalam upaya meningkatkan kompetensi dan daya saing mahasiswa...

KAITAN UMA

LOKASI FAKULTAS TEKNIK UMA

KAMPUS I :

Jln. Kolam Nomor 1 Medan Estate
Jln. PBSI, Medan 20223
Telepon : (061) 7360168
Call Center : 0811-6013-888

KAMPUS II :

Jln. Sei Serayu No. 70 A, Medan 20122
Jln. Setia Budi No. 79 B, Medan 20122
Telepon : (061) 42402994
Call Center : 0811-6013-888

Silahkan kunjungi juga website Prodi :

  • Teknik Sipil : sipil.uma.ac.id
  • Teknik Elektro : elektro.uma.ac.id
  • Teknik Mesin : mesin.uma.ac.id
  • Arsitektur : arsitektur.uma.ac.id
  • Teknik Informatika : informatika.uma.ac.id

 

Copyright © 2016 - 2026 Prodi Teknik Industri- Universitas Medan Area